Sign In | Join Free | My fazendomedia.com |
|
Place of Origin : Guangdong, China (Mainland)
Certification : CE
Model Number : YHS-718
MOQ : 1 pcs
Price : the best price
Packaging Details : carton box for outer ,gift box for unit
Delivery Time : According to customers' need.
Payment Terms : T/T ;Western Union; MoneyGram
Supply Ability : 120000 pcs per/month
YHS-718 Volt / mA Process Loop Calibrator Similiar to FLUKE 715 , Udate of YHS717 Calibrator
Quick Detail:
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.025%, superior to other loop calibrators in this price range.
1 µA resolution for mA source, simulate and measure.
Push button 25% steps for fast, easy linearity checks.
0-100% “span check” for fast confirmation of zero and span.
Features
The fast, one-handed tool for loop checks. Just click to calibrate.
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
Large display and simple, quick-click interface for easy one-handed operation.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.025%, superior to other loop calibrators in this price range.
1 µA resolution for mA source, simulate and measure.
Push button 25% steps for fast, easy linearity checks.
0-100% “span check” for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
New R&D Features by Yehai
Measures o-10v DC&0-100mV DC with accuracy 0.02%
Output o-10v DC&0-100mV DC with accuracy 0.02%
0 - 20 mA or 4 - 20 mA output range could be set manually
rechargabel lithiumion battery pack.
Push button 25% steps or fast,easy linerity checks
Specifications
Current Measurement |
Range: |
0 to 24 mA |
Resolution: |
0.001 mA |
|
Accuracy: |
0.02%+4dgt |
|
Current Sourcing |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.02%+4dgt |
|
Drive Capability: |
To 1000 Ω at 20mA |
|
Current Simulation |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.02%+4dgt |
|
Ext. loop voltage requirement: |
12-30 V |
|
Loop Power |
While measuring mA, 24 V |
|
Voltage measurement |
Range: |
0 to 10 V DC |
Resolution: |
1 mV |
|
Accuracy: |
0.02% +4Rdg |
mV DC Measure |
Range |
0 to10v DC |
|
Resolution |
1mV |
|
Accuracy |
0.02% +4Rdg |
V DC Ouput |
Range |
0 to 100mV |
|
Resolution |
0.01mV |
|
Accuracy |
0.02% +4Rdg |
mV DC Ouput |
Range |
0 to 100mV |
|
Resolution |
0.01mV |
|
Accuracy |
0.02% +4Rdg |
Environmental Specifications
Operating Temperature -10ºC to 55ºC
Storage Temperature -40ºC to 60ºC
Humidity (Without Condensation) 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)
Temperature Coefficient -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC
Safety Specifications
Maximum voltage 30V
Mechanical & General Specifications
Size 152 x 70 x 41 mm
Weight 224 g (340 g including holster)
Batteries One 9V battery Alkaline(YHS-707) , One 9V battery
Warranty Two years
Shock & Vibration per MIL-T-28800 for a Class 2 Instrument
Display current and % of span Yes
Auto step, auto ramp Yes
Span Check Yes
We can provide OEM Service for customers completely
Accessories Included
Item |
Description |
Quantity |
1 |
A 7.4v Li-polymer battery |
1 |
2 |
Test Lead red Test Lead black |
1 1 |
3 |
Bending test plug wire clip (red) Bending test plug wire clip(black) |
1 1 |
4 |
Adapeter(DC 10V 1A) |
1 |
5 |
Instruction Sheet |
1 |
6 |
Certification |
1 |
Loop Calibrator YHS-717
This loop calibrator is designed with output current, Simulate output current, output voltage function,
it is used for detecting and debugging automatic control equipment in industry scene
Features
• Measures V dc to 28 V.
• 0 - 20 mA or 4 - 20 mA default start up modes.
• Push button 25% steps for fast, easy linearity checks.
• 1 µA resolution for mA source, simulate and measure.
• 0-100% “span check” for fast confirmation of zero and span.
• HART ™ mode connects 250 Ω resistor in series with
24 V loop for compatibility with HART communicators.
• 24 volt internal loop supply, so you can power and read
a transmitter at the same time without carrying a DMM.
•Selectable slow ramp, fast ramp, and step ramp to
provide smooth outputs for valve slewing and loop
• Innovative output adjustment dial with 1 µA and 100 resolution.
• Single 9V rechargeable battery that is easily changed without braking calibration seal
• Simultaneous mA and % readout for quick, easy interpretation of readings.
• mA accuracy of 0.025%, superior to other loop calibrators in this price range.
• Large display and simple, quick-click interface for easy one-handed operation.
functional tests.
Specifications
Current Measurement |
Range: |
0 to 24 mA |
Resolution: |
0.001 mA |
|
Accuracy: |
0.02% Rdg + 4 LSD |
|
Current Sourcing |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.02% Rdg + 4 LSD |
|
Drive Capability: |
1200 Ω; 950 Ω at 20 mA in HART mode |
|
Current Simulation |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.02% Rdg + 4 LSD |
|
Ext. loop voltage requirement: |
12-30 V |
|
Loop Power |
While measuring mA, 24 V |
|
Voltage measurement |
Range: |
0 to 28 V DC |
Resolution: |
1 mV |
|
Accuracy: |
0.02% Rdg + 4 LSD |
![]() |
YHS-718 Volt / mA Process Loop Calibrator Similiar to FLUKE 715 , Udate of YHS717 Calibrator Images |