Sign In | Join Free | My fazendomedia.com |
|
Place of Origin : Guangdong, China (Mainland)
Model Number : YHS-7007
Certification : CE
MOQ : 1 sample order
Price : the best price
Packaging Details : carton box for outer ,gift box for unit
Delivery Time : According to customers' need.
Payment Terms : T/T Western Union MoneyGram
Supply Ability : 8000 pcs per/month
0.025% mA Accuracy Process Loop Calibrator with Large Display , YHS-7007
Quick Detail:
mA accuracy of 0.025%, superior to other loop calibrators in this price range.
1 µA resolution for mA source, simulate and measure.
Push button 25% steps for fast, easy linearity checks.
0-100% “span check” for fast confirmation of zero and span
Features:
The fast, one-handed tool for loop checks. Just click to calibrate.
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
Large display and simple, quick-click interface for easy one-handed operation.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.025%, superior to other loop calibrators in this price range.
1 µA resolution for mA source, simulate and measure.
Push button 25% steps for fast, easy linearity checks.
0-100% “span check” for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Measures V dc to 28 V.
Single 9V battery that is easily changed without braking calibration seal
0 - 20 mA or 4 - 20 mA default start up modes.
Innovative output adjustment dial with 1 µA and 100 resolution.
HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.
Specifications
Current Measurement |
Range: |
0 to 24 mA |
Resolution: |
0.001 mA |
|
Accuracy: |
0.025% Rdg + 2 LSD |
|
Current Sourcing |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.025% Rdg + 2 LSD |
|
Drive Capability: |
1200 Ω; 950 Ω at 20 mA in HART mode |
|
Current Simulation |
Range: |
0 to 20 mA or 4 to 20 mA |
Accuracy: |
0.025% Rdg + 2 LSD |
|
Ext. loop voltage requirement: |
12-30 V |
|
Loop Power |
While measuring mA, 24 V |
|
Voltage measurement |
Range: |
0 to 28 V DC |
Resolution: |
1 mV |
|
Accuracy: |
0.025% Rdg + 2 LSD |
Environmental Specifications
Safety Specifications
Mechanical & General Specifications
![]() |
0.025% mA Accuracy Process Loop Calibrator with Large Display , YHS-7007 Images |